PRLG

PRLG
DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRLG10TLBTLB 10 psi 25 psi 0.5 - 7 gpm tape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
PRLG15TLBTLB 15 psi 25 psi 0.5 - 7 gpm tape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
           
PRLG105LB5LB 10 psi 50 psi 0.5 - 7 gpm 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG155LB5LB 15 psi 50 psi 0.5 - 7 gpm 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG205LB5LB 20 psi 50 psi 0.5 - 7 gpm 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
           
PRLG106LB6LB 10 psi 50 psi 0.5 - 7 gpm 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG156LB6LB 15 psi 50 psi 0.5 - 7 gpm 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG206LB6LB 20 psi 50 psi 0.5 - 7 gpm 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
           
PRLG103FH3MH 10 psi 90 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG153FH3MH 15 psi 95 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG203FH3MH 20 psi 100 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG253FH3MH 25 psi 105 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG303FH3MH 30 psi 110 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG353FH3MH 35 psi 115 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
PRLG403FH3MH 40 psi 120 psi 0.5 - 7 gpm ¾" F hose ¾" M hose
           
PRLG103F3M 10 psi 90 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG153F3M 15 psi 95 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG203F3M 20 psi 100 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG253F3M 25 psi 105 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG303F3M 30 psi 110 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG353F3M 35 psi 115 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT
PRLG403F3M 40 psi 120 psi 0.5 - 7 gpm ¾" F NPT ¾" M NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.