PRLG (Metric)

PRLG
DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRLG10TLBTLB 0.69 bar 1.72 bar 114 - 1590 L/hr tape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
PRLG15TLBTLB 1.03 bar 1.72 bar 114 - 1590 L/hr tape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
           
PRLG105LB5LB 0.69 bar 3.45 bar 114 - 1590 L/hr 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG155LB5LB 1.03 bar 3.45 bar 114 - 1590 L/hr 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG205LB5LB 1.38 bar 3.45 bar 114 - 1590 L/hr 500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
           
PRLG106LB6LB 0.69 bar 3.45 bar 114 - 1590 L/hr 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG156LB6LB 1.03 bar 3.45 bar 114 - 1590 L/hr 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG206LB6LB 1.38 bar 3.45 bar 114 - 1590 L/hr 600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
           
PRLG103FH3MH 0.69 bar 6.20 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG153FH3MH 1.03 bar 6.55 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG203FH3MH 1.38 bar 6.89 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG253FH3MH 1.72 bar 7.24 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG303FH3MH 2.07 bar 7.58 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG353FH3MH 2.41 bar 7.93 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
PRLG403FH3MH 2.76 bar 8.27 bar 114 - 1590 L/hr ¾" F hose ¾" M hose
           
PRLG103F3M 0.69 bar 6.20 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG153F3M 1.03 bar 6.55 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG203F3M 1.38 bar 6.89 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG253F3M 1.72 bar 7.24 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG303F3M 2.07 bar 7.58 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG353F3M 2.41 bar 7.93 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT
PRLG403F3M 2.76 bar 8.27 bar 114 - 1590 L/hr ¾" F NPT ¾" M NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.