PRMP DESIGN CRITERIA |
Preset Operating Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
PRMP153FH3MH | 15 psi | 95 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP203FH3MH | 20 psi | 100 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP253FH3MH | 25 psi | 105 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP303FH3MH | 30 psi | 110 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP353FH3MH | 35 psi | 115 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP403FH3MH | 40 psi | 120 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
PRMP103F3M | 10 psi | 90 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP153F3M | 15 psi | 95 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP203F3M | 20 psi | 100 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP253F3M | 25 psi | 105 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP303F3M | 30 psi | 110 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP353F3M | 35 psi | 115 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP403F3M | 40 psi | 120 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
PRMP10TLBTLB | 10 psi | 25 psi | 0.5 - 7 gpm | tape (5/8") | tape (5/8") |
PRMP15TLBTLB | 15 psi | 25 psi | 0.5 - 7 gpm | tape (5/8") | tape (5/8") |
PRMP155LB5LB | 10 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
PRMP155LB5LB | 15 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
PRMP205LB5LB | 20 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
PRMP156LB6LB | 10 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
PRMP156LB6LB | 15 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
PRMP206LB6LB | 20 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.