7125 PC Impact Sprinkler

7125 PC SPRINKLER
DESIGN CRITERIA
psi
40 50 60 70
#14 Nozzle (7/32")  
Flow (gpm) 9.20 10.10 10.9 11.8
Radius at 1.5 ft ht (ft) 56 58 58 63
Radius at 6.0 ft ht (ft) 57 61 63 65
#16 Nozzle (1/4")  
Flow (gpm) 11.1 12.3 13.5 14.8
Radius at 1.5 ft ht (ft) 60 61 62 65
Radius at 6.0 ft ht (ft) 61 64 67 69
#18 Nozzle (9/32")  
Flow (gpm) 13.3 15.2 16.6 18.0
Radius at 1.5 ft ht (ft) 60 63 66 71
Radius at 6.0 ft ht (ft) 62 68 71 74
#20 Nozzle (5/16")  
Flow (gpm) 16.4 18.1 19.8 21.9
Radius at 1.5 ft ht (ft) 63 66 71 75
Radius at 6.0 ft ht (ft) 64 73 74 77
#22 Nozzle (11/32")  
Flow (gpm) 19.0 21.3 23.0 25.4
Radius at 1.5 ft ht (ft) 63 70 77 78
Radius at 6.0 ft ht (ft) 65 75 76 79
#24 Nozzle (3/8")  
Flow (gpm) 23.0 24.4 27.9 31.0
Radius at 1.5 ft ht (ft) 67 73 78 81
Radius at 6.0 ft ht (ft) 67 77 79 82

Sprinkler performance may vary with actual field conditions. Stream heights range from 8.5 to 15.5 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 1.5 ft.