PRU-LV
DESIGN CRITERIA |
Preset Operating Pressure |
Maximum Inlet Pressure |
Maximum Flow |
Inlet Sizes |
Outlet Sizes |
| PRU LV 10 |
0.69 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 15 |
1.03 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 20 |
1.38 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 25 |
1.72 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 30 |
2.07 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 40 |
2.76 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 50 |
3.45 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
| PRU LV 60 |
4.14 bar |
8.62 bar |
up to 22713 L/hr |
2" F NPT, 2" F BSPT |
2" F NPT, 2" F BSPT |
The PRU-LV limits downstream pressure to no more than 1.03 bar above regulated pressure during static (no flow) conditions.
Recommended for outdoor use only. Not NSF certified.